Please ensure Javascript is enabled for purposes of website accessibility

SmartPro SMART1000RM2U, LCD, 1000 VA/800 W, Sine Wave, 2U Rackmount/Tower UPS

Quantity:
  • SKU: 2930
  • Manufacturer: TRIPP LITE
  • MPN: SMART1000RM2U
  • Availability: USUALLY SHIPS WITHIN 3-5 DAYS
Starting At
$627.94
Quantity:
SmartPro SMART1000RM2U, LCD, 1000 VA/800 W, Sine Wave, 2U Rackmount/Tower UPS

Tripp Lite's SMART 1000RM2U intelligent, line-interactive sine wave rack/tower uninterruptible power supply prevents data loss, downtime and equipment damage due to power outages, voltage fluctuations and transient surges.

  • 1kVA / 1000VA / 800W line interactive 2U rack/tower UPS
  • Corrects brownouts and overvoltages from 83V to 147V
  • 95% line-mode efficiency
  • USB, RS232, EPO and slot for SNMPWEBCARD option
OUTPUT
Output Volt Amp Capacity (VA) 1000
Output kVA Capacity (kVA) 1.0
Output Watt Capacity (Watts) 800
Power Factor 0.8
Nominal Output Voltage(s) Supported 110V; 115V; 120V
Nominal Voltage Details 120v nominal output in battery mode
Frequency Compatibility 60 Hz
Output Voltage Regulation (Line Mode) -21%, +8%
Output Voltage Regulation (Battery Mode) +/- 5%
Output Receptacles (6) 5-15R
Load Management Receptacles Two switchable two-outlet 5-15R load banks
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
INPUT
Rated input current (Maximum Load) 9.2A
Nominal Input Voltage(s) Supported 120V AC
UPS Input Connection Type 5-15P
Input Circuit Breakers 15A
UPS Input Cord Length (ft.) 10
Recommended Electrical Service 15A 120V
Input Phase Single-Phase
BATTERY
Full Load Runtime (min.) 5.3 min. (800w)
Half Load Runtime (min.) 15 min. (400w)
DC System Voltage (VDC) 24
Battery Recharge Rate (Included Batteries) Less than 4 hours from 10% to 90% (typical, full load discharge)
Internal UPS Replacement Battery Cartridge See Tripp Lite UPS Replacement battery selector
Battery Access Front panel battery access door
Battery Replacement Description Hot-swappable, user replaceable batteries
Expandable Runtime No
VOLTAGE REGULATION
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 147
Overvoltage Correction Input voltages between 128 and 147 are reduced by 12%
Undervoltage Correction Input voltages between 83 and 107 are boosted by 14%
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
Switches 3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions
Alarm Cancel Operation Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
Audible Alarm Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 570
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
PHYSICAL
Included Mounting Accessory Description 4 post rackmount installation accessories included
Installation Form Factors Supported with Optional Accessories 2 post rackmount(2POSTRMKITWM); Wallmount(2POSTRMKITWM); Tower(2-9USTAND)
Primary Form Factor Rackmount
UPS Power Module Dimensions (hwd, in.) 3.45 x 17.35 x 12.5
Rack Height (U Spaces) 2
Minimum Required Rack Depth (inches) 15.5
UPS Power Module Weight (lbs.) 35.4
UPS Shipping Dimensions (hwd / in.) 9 x 24 x 20.2
Shipping Weight (lbs.) 46.4
Cooling Method Fan
UPS Housing Material Steel
Minimum Required Rack Depth (mm) 394
Primary UPS Height (mm) 88
Primary UPS Width (mm) 441
Primary UPS Depth (mm) 318
Shipping Height (mm) 229
Shipping Width (mm) 610
Shipping Depth (mm) 513
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 134
Battery Mode BTU / Hr. (Full Load) 600
AC Mode Efficiency Rating (100% Load) 95%
COMMUNICATIONS
Communications Interface USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Network Management Cards SNMPWEBCARD; TLNETCARD; WEBCARDLX
Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Communications Cable USB and DB9 cabling included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network UPS Tools Compatibility NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite
LINE / BATTERY TRANSFER
Transfer Time 4 milliseconds (AC to battery), 2 milliseconds (Battery to AC)
Low Voltage Transfer to Battery Power (Setpoint) 83
High Voltage Transfer to Battery Power (Setpoint) 147
SPECIAL FEATURES
Grounding Lug Back panel grounding lug
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Hot swappable batteries
CERTIFICATIONS
UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI)
WARRANTY
Product Warranty Period (Worldwide) 2-year warranty, 3 year with registration. Note: Registration is requiredfor 3-year warranty.
Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance